Product NO. GME-C601 Envrionment Administration Technique ISO9001/14001 Certificate CE/RoHS/SGS Tolerance +/- .05mm Design Variety Gme-C601 Magnetization Path Axial/Radial/Multi-Poles Magnetization Functioning Temp. eighty-two hundred Diploma Centigrade Transportation by Sea, by Air, by Express Payment T/T, Paypal, Western Union Direct Time 15-25days Trademark GME Transport Package deal Carton, Wooden Case, Anti-Magnetized Bundle Specification Customized produced Origin Zhejiang Ningbo/ Zhejiang Xiamen HS Code 850511100
Item Description
Introduction ofmagnetic shaft coupling
Magneticshaft couplingis a new variety of coupling, which connects motor and machine by permanent magnetic pressure.
They areconsisted of exterior rotor, inside rotor and isolating addresses.
They operate in the sealed magnetic drivepumps, which transporting risky, flammable, explosive and poisonous solutions with no leakage.
These magneticshaft couplingscan be utilised to connect equipment pumps , screw pumps, centrifugal pumps, and so on. with all sorts of electricmotor or equipment box.
Magneticshaft couplingare extensively utilised in different industries and fields, such as chemical,papermaking, foodstuff,pharmacy, and so on.
Positive aspects ofmagnetic shaft coupling
» Elimination of fluid leakage from the pump shaft.
» Vibrations are not transmitted to the pump.
» No upkeep necessary for magnetic couplings.
» Making use of magnetic couplings makes it possible for use of standard pumps with no expensive mechanical seals.
» No extra value for acquiring mechanical seal spare areas and upkeep.
Technical drawing ofmagnetic shaft coupling
Specification ofmagnetic shaft coupling
ItemInternal Rotor(mm)Exterior Rotor(mm)Isolating Masking(mm)ABCDEFGShaft PinHIJLNMPQRSTUGME03-3LM00&Phi35-&Phi1026-18-M6X12&Phi42&Phi60&Phi50466-M4&Phi40&Phi504-&Phi5.4&Phi38&Phi6066GME03-5MM00&Phi42-&Phi122741813.8M6X16&Phi49&Phi72&Phi60464-&Phi6.7&Phi52&Phi604-&Phi6.seven&Phi44&Phi7488GME03-16LM00&Phi56-&Phi124542513.8M6X16&Phi63&Phi89&Phi80756-M5&Phi70&Phi754-&Phi6.7&Phi58&Phi8988GME03-16LM01&Phi56-&Phi124542513.8M6X16&Phi63&Phi89&Phi80754-M5&Phi70&Phi754-&Phi6.seven&Phi58&Phi89610GME03-16MM00&Phi56-&Phi124542513.8M6X16&Phi63&Phi89&Phi80756-M5&Phi70&Phi754-&Phi6.7&Phi58&Phi8988GME03-22LM00&Phi88-&Phi202962522.8M8X20&Phi97&Phi122&Phi110708-M6&Phi98&Phi1086-&Phi6.seven&Phi91&Phi12288GME03-30LM00&Phi88-&Phi204863022.8M8X20&Phi97&Phi122&Phi110818-M6&Phi98&Phi1086-&Phi6.seven&Phi91&Phi12288GME03-40LM00&Phi101-&Phi254982828.3M10X20&Phi109&Phi140&Phi124838-M8&Phi110&Phi1268-&Phi6.seven&Phi103&Phi140126GME03-50LM00&Phi107-&Phi207063022.8M6X16&Phi113.four&Phi145&Phi135804-M6&Phi126&Phi13312-&Phi8.seven&Phi109&Phi1531215GME03-65LM00&Phi101-&Phi257784528.3M10X20&Phi109&Phi140&Phi1241118-M8&Phi110&Phi1268-&Phi6.seven&Phi103&Phi140126GME03-80LM00&Phi106-&Phi3265102136.5M6X25&Phi115&Phi145&Phi135824-M6&Phi127&Phi1356-&Phi8.7&Phi110&Phi1531318GME03-80LM00&Phi141&Phi92&Phi4065124543.3M12X25&Phi152&Phi180&Phi1681008-M8&Phi154&Phi1648-&Phi6.seven&Phi145&Phi180128GME03-100LM00&Phi131&Phi82&Phi32801024.535.3M8X35&Phi139&Phi170&Phi1601004-M6&Phi152&Phi1588-&Phi8.seven&Phi133&Phi1781421GME03-110LH00&Phi141&Phi92&Phi4085105043.3M12X25&Phi152&Phi184&Phi16811512-M8&Phi156&Phi16412-&Phi6.seven&Phi145&Phi180123GME03-110LM00&Phi141&Phi92&Phi3580105538.3M12X25&Phi152&Phi180&Phi16811512-M8&Phi154&Phi16412-&Phi6.seven&Phi145&Phi180123GME03-140LM00&Phi141&Phi92&Phi40110128043.3M12X25&Phi152&Phi190&Phi17014512-M10&Phi154&Phi16412-&Phi6.7&Phi145&Phi180123GME03-180LM00&Phi141&Phi92&Phi40140129543.3M12X25&Phi152&Phi190&Phi17017512-M10&Phi154&Phi16412-&Phi6.7&Phi145&Phi180123GME03-220LM00&Phi141&Phi92&Phi481601411051.8M12X25&Phi152&Phi190&Phi17019512-M10&Phi154&Phi16412-&Phi6.7&Phi145&Phi180123GME03-300LM00&Phi162-&Phi65100186069.4&Phi170&Phi198&Phi18812312-M6&Phi180&Phi19212-&Phi11&Phi163.5&Phi2181610GME03-400LH00&Phi195-&Phi701272010779.9M12X25&Phi203&Phi234&Phi2221526-M6&Phi212&Phi16412-&Phi11&Phi198&Phi2781622
Software ofmagnetic shaft coupling
The potential to hermetically independent two areas even though continuing to transmit mechanical electricity from oneto the other helps make these couplings ideal for purposes where prevention of cross contamination is crucial.For instance: hydraulic sectors, dosing techniques, compressors, sterilizers, industrial ovens, biotechnology,subsea gear, pharmaceutical sector, chemical market, meals industry, generators and mixers.
Operation rules ofmagnetic shaft coupling
The magnetic coupling operates by using the electricity generated by long lasting magnets. No exterior powersupply is needed. These are long term magnets not electro magnets.
Packing Strategy ofmagnetic shaft coupling
Double strength corrugated Carton andWood caseSea Packing.
Standard Data.
Design NO. GME-C601 Envrionment Administration Method ISO9001/14001 Certification CE/RoHS/SGS Tolerance +/- .05mm Product Number Gme-C601 Magnetization Path Axial/Radial/Multi-Poles Magnetization Working Temp. eighty-200 Diploma Centigrade Transportation by Sea, by Air, by Specific Payment T/T, Paypal, Western Union Direct Time 15-25days Trademark GME Transportation Package Carton, Wood Situation, Anti-Magnetized Package Specification Personalized produced Origin Zhejiang Ningbo/ Zhejiang Xiamen HS Code 850511100
Merchandise Description
Buyer Query & Answer Question some thing for much more specifics ()
Introduction ofmagnetic shaft coupling
Magneticshaft couplingis a new variety of coupling, which connects motor and device by permanent magnetic drive.
They areconsisted of external rotor, inner rotor and isolating handles.
They operate in the sealed magnetic drivepumps, which transporting volatile, flammable, explosive and poisonous solutions with no leakage.
These magneticshaft couplingscan be employed to connect gear pumps , screw pumps, centrifugal pumps, and so on. with all types of electricmotor or equipment box.
Magneticshaft couplingare broadly employed in a variety of industries and fields, such as chemical,papermaking, foodstuff,pharmacy, and so on.
Benefits ofmagnetic shaft coupling
» Elimination of fluid leakage from the pump shaft.
» Vibrations are not transmitted to the pump.
» No maintenance required for magnetic couplings.
» Employing magnetic couplings allows use of regular pumps with out expensive mechanical seals.
» No added value for acquiring mechanical seal spare components and upkeep.
Specialized drawing ofmagnetic shaft coupling
Specification ofmagnetic shaft coupling
ItemInternal Rotor(mm)Exterior Rotor(mm)Isolating Covering(mm)ABCDEFGShaft PinHIJLNMPQRSTUGME03-3LM00&Phi35-&Phi1026-eighteen-M6X12&Phi42&Phi60&Phi50466-M4&Phi40&Phi504-&Phi5.four&Phi38&Phi6066GME03-5MM00&Phi42-&Phi122741813.8M6X16&Phi49&Phi72&Phi60464-&Phi6.seven&Phi52&Phi604-&Phi6.seven&Phi44&Phi7488GME03-16LM00&Phi56-&Phi124542513.8M6X16&Phi63&Phi89&Phi80756-M5&Phi70&Phi754-&Phi6.seven&Phi58&Phi8988GME03-16LM01&Phi56-&Phi124542513.8M6X16&Phi63&Phi89&Phi80754-M5&Phi70&Phi754-&Phi6.seven&Phi58&Phi89610GME03-16MM00&Phi56-&Phi124542513.8M6X16&Phi63&Phi89&Phi80756-M5&Phi70&Phi754-&Phi6.7&Phi58&Phi8988GME03-22LM00&Phi88-&Phi202962522.8M8X20&Phi97&Phi122&Phi110708-M6&Phi98&Phi1086-&Phi6.7&Phi91&Phi12288GME03-30LM00&Phi88-&Phi204863022.8M8X20&Phi97&Phi122&Phi110818-M6&Phi98&Phi1086-&Phi6.seven&Phi91&Phi12288GME03-40LM00&Phi101-&Phi254982828.3M10X20&Phi109&Phi140&Phi124838-M8&Phi110&Phi1268-&Phi6.seven&Phi103&Phi140126GME03-50LM00&Phi107-&Phi207063022.8M6X16&Phi113.4&Phi145&Phi135804-M6&Phi126&Phi13312-&Phi8.seven&Phi109&Phi1531215GME03-65LM00&Phi101-&Phi257784528.3M10X20&Phi109&Phi140&Phi1241118-M8&Phi110&Phi1268-&Phi6.7&Phi103&Phi140126GME03-80LM00&Phi106-&Phi3265102136.5M6X25&Phi115&Phi145&Phi135824-M6&Phi127&Phi1356-&Phi8.7&Phi110&Phi1531318GME03-80LM00&Phi141&Phi92&Phi4065124543.3M12X25&Phi152&Phi180&Phi1681008-M8&Phi154&Phi1648-&Phi6.7&Phi145&Phi180128GME03-100LM00&Phi131&Phi82&Phi32801024.535.3M8X35&Phi139&Phi170&Phi1601004-M6&Phi152&Phi1588-&Phi8.seven&Phi133&Phi1781421GME03-110LH00&Phi141&Phi92&Phi4085105043.3M12X25&Phi152&Phi184&Phi16811512-M8&Phi156&Phi16412-&Phi6.seven&Phi145&Phi180123GME03-110LM00&Phi141&Phi92&Phi3580105538.3M12X25&Phi152&Phi180&Phi16811512-M8&Phi154&Phi16412-&Phi6.7&Phi145&Phi180123GME03-140LM00&Phi141&Phi92&Phi40110128043.3M12X25&Phi152&Phi190&Phi17014512-M10&Phi154&Phi16412-&Phi6.7&Phi145&Phi180123GME03-180LM00&Phi141&Phi92&Phi40140129543.3M12X25&Phi152&Phi190&Phi17017512-M10&Phi154&Phi16412-&Phi6.seven&Phi145&Phi180123GME03-220LM00&Phi141&Phi92&Phi481601411051.8M12X25&Phi152&Phi190&Phi17019512-M10&Phi154&Phi16412-&Phi6.seven&Phi145&Phi180123GME03-300LM00&Phi162-&Phi65100186069.four&Phi170&Phi198&Phi18812312-M6&Phi180&Phi19212-&Phi11&Phi163.5&Phi2181610GME03-400LH00&Phi195-&Phi701272010779.9M12X25&Phi203&Phi234&Phi2221526-M6&Phi212&Phi16412-&Phi11&Phi198&Phi2781622
Software ofmagnetic shaft coupling
The potential to hermetically different two areas whilst continuing to transmit mechanical power from oneto the other helps make these couplings best for purposes the place prevention of cross contamination is essential.For instance: hydraulic sectors, dosing programs, compressors, sterilizers, industrial ovens, biotechnology,subsea equipment, pharmaceutical sector, chemical market, food market, generators and mixers.
Operation rules ofmagnetic shaft coupling
The magnetic coupling functions by using the electrical power created by everlasting magnets. No external powersupply is necessary. These are long lasting magnets not electro magnets.
Packing Method ofmagnetic shaft coupling
Double toughness corrugated Carton andWood caseSea Packing.